Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number PR61-4320F with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number PR61-4320F It is listed as Resistor Fixed Wire Wound Induct. component manufactured by Shallcross Inc, specifically under CAGE Code 54294. It is also accompanied by the NSN 5905006271137 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5905 Resistors.
NSN Information for Part Number PR61-4320F with NSN 5905-00-627-1137, 5905006271137
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-627-1137 Item Description: Resistor Fixed Wire Wound Induct | 5905 | 006271137 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Pr61-4320f | E | 1 | 5 |
Characteristics Data of NSN 5905-00-627-1137, 5905006271137
MRC | Criteria | Characteristic |
---|---|---|
AAPP | ELECTRICAL RESISTANCE | 432.000 OHMS |
SR-1 | MANUFACTURERS CODE | 81349 |
AARB | TERMINAL TYPE | WIRE LEAD |
ADAQ | BODY LENGTH | 0.560 INCHES NOMINAL |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | RWR89S4320FR |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000/+1.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+275.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
ABPM | BODY DIAMETER | 0.187 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 3.000 FREE AIR |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39007 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MILR39007-11 |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -20.0 TO 20.0 |
SR-1 | SPEC/STD CONTROLLING DATA | |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |