Using the Request for Quote (RFQ) form provided on this page, you can request competitive procurement options on part number 6150W38P013 with rapid responses always offered by our staff. To ensure that you locate and procure exactly what you need with ease, we list parts with as much information as we can. For example, part number 6150W38P013 It is listed as Resistor Variable Nonwire Wound. component manufactured by Ametek Inc Div Aerospace And Defe, specifically under CAGE Code 97424. It is also accompanied by the NSN 5905011078752 for ease of organization, the first digits of the NSN indicating that the part belongs to FSC 5905 Resistors.
NSN Information for Part Number 6150W38P013 with NSN 5905-01-107-8752, 5905011078752
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-107-8752 Item Description: Resistor Variable Nonwire Wound | 5905 | 011078752 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6150w38p013 | 5 | 8 | E |
Characteristics Data of NSN 5905-01-107-8752, 5905011078752
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AAQL | BODY STYLE | RECTANGULAR |
ABJT | TERMINAL LENGTH | 0.172 INCHES MINIMUM |
ADAU | BODY HEIGHT | 0.250 INCHES NOMINAL |
AAPN | SECTION QUANTITY | 1 |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
SR-1 | MANUFACTURERS CODE | 81349 |
AXGY | MOUNTING METHOD | TERMINAL |
AEFK | MAXIMUM STARTING TORQUE | 2.00 INCH-OUNCES |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-R-39035/4 |
AEFM | MAXIMUM STOP TORQUE | 4.00 INCH-OUNCES |
SR-1 | SPEC/STD CONTROLLING DATA | |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 215.0 MINIMUM |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | RJR50FP503P |
AEFL | MAXIMUM RUNNING TORQUE | 2.00 INCH-OUNCES |
AFJN | FRAGILITY FACTOR | RUGGED |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 50.000 KILOHMS SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.25 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
APXH | TERMINAL LOCATION | REAR END |
ADAQ | BODY LENGTH | 0.250 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.250 INCHES NOMINAL |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 215.0 MINIMUM |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39035 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39035/4 GOVERNMENT SPECIFICATION |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.100 |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |